The DDX 9160 and DDX 9161 are the newest PD detectors from Haefely for AC, DC, and RIV partial discharge measurements. The fully digital state-of-the-art detectors can accommodate up to four simultaneous PD/RIV and Voltage inputs. The modular design fits a wide range of PD detection applications. Conventional AC & DC PD measurements according to IEC 60270 or RIV measurements according to NEMA and CISPR standards are covered.
The DDX 9160 is lightweight, portable, and battery operated, making it ideal for on-site PD measurements or for power transformer PD measurements using the bushing tap method.
The DDX 9161 is a laboratory optimized instrument fitted with a low-noise AC supply for enhanced measurement sensitivity.
Haefely’s CaMS software platform provides the most modern, flexible, and user-configurable PD application software on the market. The software enables the controlling of single channel, multi-channel (up to 4 channels per unit) and/or multi-detectors (connected in a daisy chain). A dark mode display includes all the required PD analysis tools such as information display, pulse diagram, PRPD pattern (fingerprinting), data logger, and more. The number of meter indicators, as well as their size, can be selected. Reports can be easily created in pdf format.
Fiberoptic cables provide galvanic isolation between HV test floor and the control room, ensuring the full safety of the operating personnel. Measurement sensitivity is increased with the most flexible digital filters available on the market allowing the frequency measurement band to be shifted into a less noisy range and suppressing frequency-dependent noise.
Datasheets:
Brochure:
DDX 9160 & DDX 9161 Features
AC and DC measuring modes
User defined measuring band
Modular design, 1 to 4 channels, and capability to daisy chain many detectors
Simultaneous RIV and PD reading
Phase Resolved PD (PRPD) patterns for fingerprinting
High resolution spectrum analyzer with oscilloscope
Data acquisition and test report generation
Optically decoupled from the computer
Unit can be easily upgraded (up to 12 simultaneous PD/RIV readings)
Reduces training time – The modern software makes the use of the device easier than ever. Operators can start using the device in minutes.
PD interpretation – The phase resolved analysis and recording capabilities allow for future data analysis.
Reduce the number of required components and save space by utilizing an internal integrated measuring impedance
Combine with the AKV 9360 measuring impedance and 9231 Series (AC) or 9241 Series (AC & DC) coupling capacitors (all components can be housed in the base of the divider)