EMC Equipment

Data Line Coupling Decoupling Networks (CDNs)

 

CDN-DATA-8L:  Unshielded Asymmetrical Data Lines

 coupling decoupling Data_208_20L

CDN-DATA-8L is an easy to use and versatile coupling decoupling network for unsymmetrical unshielded lines.  This CDN is used to induce up to 6kV Surge Combination Wave (IEC 61000-4-5) and Ring Wave (IEC 61000-4-12)  disturbances on devices with up to 8 data lines (4 pair).  The CDN-DATA-8L can be used with the IMU Series of transient generators to meet test requirements per IEC 61000-4-5 Ed.3 Figure 9.  


CDN-UTP8 - Unshielded Symmetrical Data Lines

Data Line CDN-UTP8

CDN-UTP8 ED3 is an easy to use and versatile coupling decoupling network for symmetrical unshielded lines.  This CDN is used to induce up to 6kV Surge Combination Wave (IEC 61000-4-5) and Telecom wave (10/700us) disturbances on devices with up to 8 data lines (4 pair).  This CDN is designed for high speed Ethernet testing applications up to 1 gigabit speeds. The CDN-UTP8 ED3 can be used with the IMU Series of transient generators to meet test requirements per IEC 61000-4-5 Ed.3 Figure 10 and 11.  


Shielded Asymmetrical and Symmetrical Data Lines:

Network CDNs Shielded Data Lines

Shielded symmetrical and asymmetrical data line testing can be performed with the IMU4000 or IMU3000 generator by applying Surge Combination Wave (IEC 61000-4-5) disturbances directly on to the shield.  

 