High voltage cable test equipment from BAUR eliminates the days of painstakingly hauling out a VLF source along with a Tan Delta System and separate user interface (PC) are over. Today testing practices are getting smarter with Monitored Withstand Testing.
Monitored withstand testing combines Very Low Frequency testing or VLF cable testing with Tan Delta measurements at the same time. Partial Discharge testing is then thrown into the mix for a complete picture of the cable system insulation health and current state. This approach significantly reduces costly outages as well as the cable system's time under test and begins a proactive condition based maintenance program vs. time based maintenance.
|
 |
TrueSinus Digital Technology
BAUR's Truesinus® digital technology is state-of-the-art very low frequency VLF high voltage cable test equipment .
This unique system with its truly sinusoidal voltage shape allows non-destructive very low frequency testing or VLF testing of high voltage cables according to VDE, IEC und IEEE* specifically IEEE 400.2. Failures can occur in any high voltage cable installation. These VLF cable tester systems reliably detects faulty spots or determines that the cable is ready for operation.
|
| |
|

Frida
|
Frida and Frida TD is a Portable VLF using truesinus
BAUR's Lightweight, portable and easy to use Frida Very Low Frequency VLF test set brings on-site VLF cable testing into the 21st century.
- Two versions available
- Frida - Automatic, programmable VLF hipot
- Frida TD - Perform VLF Cable testing with Tan Delta with one piece of equipment
- Output Modes +DC, -DC, VLF Sine wave (0.1-0.01Hz), VLF Square wave.
- Extendable to include Partial Discharge measurement with PD Portable
- Cable sheath testing and sheath fault location
|
| |
|

Viola
|
Viola / Viola TD VLF tester truesinus
BAUR's Two-part design VLF High Voltage Testing device, "viola"
- Two versions available
- Viola - Automatic, programmable VLF hipot
- Viola TD - Perform VLF Cable testing with Tan Delta with one piece of equipment
- Output Modes +DC, -DC, VLF Sine wave (0.1-0.01Hz), Square wave.
- Extendable to include Partial Discharge measurement with PD Portable
- Cable sheath testing and sheath fault location
|
| |
|

PHG
|
VLF Cable Diagnostic Systems PHG Series
BAUR‘s programmable high-voltage generator PHG is a VLF cable test system of the latest generation and the most powerful VLF generator of the its family
- Two versions available, PHG 70 or PHG 80
- Output Modes +DC, -DC, VLF Sine wave (0.1-0.01Hz), Square wave.
- Extendable to include Tan Delta or Partial Discharge measurement (PHG XX TD PD)
- Optimized for VLF cable diagnostics test van systems
- Ideal for cable diagnosis on plastic, PE / XLPE or EPR and paper insulated mass impregnated cables.
- Digital control with professional, self explanatory multilingual software
|
|

PGK
|
Portable DC Hipot Test Equipment BAUR PGK Series
DC Dielectric withstand testing has never been easier with these single section one part high voltage hipot testers. The PGK series hipot test equipment is especially designed to be lightweight, compact in design, user friendliness, and solid construction.
Although DC voltage testing is an old technology in developed power markets, it is by no means dispensable. It is being used for over hundreds of thousands of kilometers of existing cable networks. Their maintenance is an economic necessity and means the maximization of returns on investment for the cable network operators.
|

PD Portable
|
Portable PD System
- Most modern non-destructive partial discharge diagnostics (PD)• Identification and precise location of partial discharges in cable systems
- Measures P8D levels and locates PD sources reliably over the entire cable line
- Very easy operation via BAUR’s diagnostics software (System Software 3.3)
- Easy-to-transport, 3-part designOptimal in combination with BAUR’s mobile VLF cable test sets frida or viola
|
| |
|

Tracy
|
Partial Discharge Inductor Tracy
BAUR’s partial discharge inductor Tracy induces a signal from outside to pre-located fault location in the cable. In combination with a PD measurement system, e.g., PHG TD PD, the signal induced can be located and compared with the result of the partial discharge location. The partial discharge location can be determined precisely. |
| |
|
| |
|
| |
|

System Software 3.3
|
Baur System Software 3.3
- Asset management support with new functions and easier handling.
- Cable Testing modes included in one software program
- Cable fault location
- Cable hipot testing
- Tan Delta measurement
- Partial Discharge Measurement
- Joint searching mode
- Reporting and database asset management
|
| |
|
| |
|