 Electrostatic Discharge (ESD) Tester, Model ESD 3000
Minimize
ESD Tester, Model ESD3000
The ESD 3000 is a fully automated and programmable ESD simulator. It identifies which discharge module is installed and has a level selector button enabling the user to quickly scroll through and select the voltage from the levels appropriate to the standard and discharge mode. The set pulse count is executed with a single pull of the trigger in either air or direct contact mode. Polarity can be programmed to alternate or can be changed with the push of the +/- button at any time. Voltage can be programmed to ramp up or down or quickly changed at any time by using the up and down arrow buttons.

 

Main Features

Application Pictures

Applicable Standards

Accessories

 


Main Features: 

  • Very high accuracy and pulse repetition
  • High Quality / Rugged Design
  • Most Modular System Available
    • Upgrade over time from 16kV to 30kV
    • Each Modular Network contains all the high voltage components, allowing it to be independently calibrated and interchangeable between simulators
      • Comparative units have the discharge network tied to each gun and they cannot be interchanged and still hold a valid calibration.
      • Meets the most test standard with one system
  • Light Weight, Ergonomic Design
    • Hold it once it easy to tell why we are preferred
    • Well balanced
    • Not tethered to a base unit located on the ground,
    • Allows for easy mobility and quicker testing
  • Only rechargeable ESD simulator on the market that uses standard NiMH AA
    • Can be powered from the wall with the AC adaptor/charger
    • Runs > full day of constant use without recharging

 

  • Small housing for clear view of the test tip and test location
    • No need to strain and look around the sides of a bulky simulator

 

  • Display is located on the gun and easy for you to see test parameters during test.
     
  • Easy to use (see the Demo Video)
    • Set polarity and Voltage level very fast
    • Or program test routines to count through test spots and pulses
    • Software controllable (W/Optional TEMA)

 

Top

 

  • Can count EITHER each full discharge or each triggered pulse.
    • Keep track of how many pulses have been made, as a double check

Application Pictures:

 


(Click image for larger view)
Picture of all of the components making up a standard
ESD3000 system for 30kV testing.

 
A typical setup for testing explosive devices and detonating caps to MIL-STD-331B and other standards
This setup Includes:
ESD3000 (ESD simulator)
ESD3000 DN4 (Discharge Network)
ESD3000 RM32 (Relay Module for DNx modules)
ESD3000 SAFETY-S (safety switch for complete discharge of simulator before each test)
ESD3000-EXT (for extending the control and use of the DN or DMs remotely from the simulator)
TC-MIG24ED (test cabinet for Explosive device testing w/ safety circuit)


 

  ESD Tester for Automotive Applications
Application of the ESD3000 being used to test the airbag system of an automobile for ESD. Where the user would want to be at a safe distance if the airbag were to fire.
This setup shows:
ESD3000 (ESD simulator)
ESD3000 DNx (Discharge Network, different versions available for ISO and manufactures' standards)
ESD3000 RM32 (Relay Module for DNx modules)
ESD3000-EXT (for extending the control and use of the DN or DMs remotely from the simulator)
ESD-STAND Ed2 (an adjustable stand for the ESD3000 Simulator system)

Top

 

 ESD Testing for Fast Charging H-Fields

Testing for Fast Charging H-Fields. Tests EUTs to the effects of ESD event in close proximity.
This Setup Includes:
ESD3000 (ESD simulator)
ESD3000 DN1 (Discharge Network)
ESD3000 RM32 (Relay Module for DNx modules)
ESD3000 CNH12 (magnetic loop accessory)
 

Applicable Standards:

  • International
    • IEC 61000-4-2
    • IEC 61340-3-1 Contact
    • IEC61340-3-2 Contact
    • For more click on the matrix image
  • Automotive
    • ISO TR10604
    • ISO 14304
    • GMW 3100
    • For more click on the matrix image
  • Avionics
    • RTCA / DO-160 Air Only
    • RTCA / DO-160 AD & CD
    • For more click on the matrix image
  • Military
    • MIL-STD-464
    • MIL-STD-883
    • MIL-STD-1576
    • For more click on the matrix image

 


Click on matrix for ESD standards
Click on the image above for a full matrix of standards that the ESD3000 can meet

Top

Accessories:

ESD3000 CNH12

Accessory to ESD3000 with RM32 and DN1 to simulate rapidly changing H-field as generated at real ESD discharge. ESD3000 Accessory, CNH12

ESD3000 SAFETY-S

Safety switch to short circuit the ESD3000 output when testing explosive devices.  ESD3000 Accessory, ESD3000 Safety-S

ESD3000DM-EXT

Accessory to ESD3000DM's and DN's to separate the control and the discharge module for special applications like airbag or explosive device testing. With the ESD3000DM-EXT the control can be separated maximum 1m.  ESD3000 Accessory, ESD3000-DM EXT

ESD3000-OPTOLINK

Optical link 10m with special LEMO plug and RS232 9 pin connector to control ESD3000 from PC. Requires TEMAOptical link 10m with special LEMO plug and RS232 9 pin connector to control ESD3000 from PC. Requires TEMA  ESD3000 Accessory, ESD-OPTO Link

ESD-STAND Ed.2

Nonmetallic stand for ESD MOUSE, ESD2000, ESD3000,ESD3000DM-EXT in accordance with IEC 61000-4-2 Ed.2.  

ESD-TARGET2

2 Ohm Target with SMA connector, upper limit >3GHz. For ESD calibration / verification and comparison. Calibrated target attenuator cable chain for up to 10kV  

ESD-TARGET2 50

50 Ohm target with SMA connector according to IEC61340-3-1 and -2. Calibrated target attenuator cable chain.  

ESD-TARGET2 500

500 Ohm target with SMA connector and measuring adapter calibrated according to IEC61340-3-1. For the voltage measurement a voltage probe must be connected between TARGET and DSO e.g. TEK 613917 or equivalent
 
 

ESD-TARGET2 DN

 2 Ohm Target with SMA connector, upper limit >3GHz. For ESD calibration / verification. Calibrated target attenuator cable chain for up to 30kV. Needed for DN Networks  

ESD-VCP50

Vertical coupling plate 0.5 x 0.5m with 2m cable and 2x 470 kOhm resistors.

ESD-VERI-V

Charging voltage (up to 25kV) measurement divider 20GOhm, ratio determined by the 1MOhm input of the oscilloscope. Ratio approx. 1:20'000.  

TC-MIG24ED

Test cabinet to test explosive devices, made of acrylic glass, for EUT with max. dimensions 30x20x20cm. Insulation withstand 1.2/50µs up to max. 36kV. With interlock safety switch and warning lamps green/red.
 

Top 

 Links
Minimize